{"id":15521,"date":"2023-06-22T10:00:01","date_gmt":"2023-06-22T08:00:01","guid":{"rendered":"https:\/\/thermovent.th.staging.generation-y.net\/?p=15521"},"modified":"2026-03-06T14:21:29","modified_gmt":"2026-03-06T12:21:29","slug":"4-benefits-of-installing-a-ciculation-pump-unit-with-and-actuator","status":"publish","type":"post","link":"https:\/\/thermovent.th.staging.generation-y.net\/en\/blog\/4-benefits-of-installing-a-ciculation-pump-unit-with-and-actuator\/","title":{"rendered":"4 benefits of installing a ciculation pump unit with and actuator"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"15521\" class=\"elementor elementor-15521 elementor-15520\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7a225be9 e-flex e-con-boxed e-con e-parent\" data-id=\"7a225be9\" data-element_type=\"container\" data-settings=\"{&quot;ekit_has_onepagescroll_dot&quot;:&quot;yes&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-34eb892e elementor-widget elementor-widget-text-editor\" data-id=\"34eb892e\" data-element_type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Circulation unit is a compact set of devices, consisting on various, carefully selected components. Having a circulation unit installed brings many benefits to both the investor and the installer.<\/strong><\/p>\n<p>There are different kinds of circulation units available in the market. Some circulation units are dedicated to solid fuel-powered domestic installations, while others work well for heat pump or gas boiler systems with e.g radiators or underfloor heating installations. Below, we\u2019re discussing 4 essential benefits brought to the installer by choosing a circulation unit\u00a0with an actuator.<\/p>\n<h3><strong>1. Less selection errors<\/strong><\/h3>\n<p>As a complete unit, the GRA200, GRA300 series circulation unit\u00a0with actuator frees the installer from having to choose and match all individual fittings and accessories. The components used (progressive valve, rotary actuator, circulation pump, among others) have been selected to ensure outstanding flow control. The installer, then, doesn\u2019t have to worry about oversizing the valve or possible incompatibility, e.g. in terms of actuator type and its rotation time. The circulation unit is also equipped with a check valve\u2014a thing sometimes overlooked by installers when they go for separate devices.<\/p>\n<p>Having a circulation unit installed does reduce errors\u2014but it doesn\u2019t mean that no mistakes can be made. When choosing a device according to installation requirements, several criteria have to be followed. These are:<br \/>\u25cf\u00a0\u00a0 \u00a0system power,<br \/>\u25cf\u00a0\u00a0 \u00a0\u0394T of the system,<br \/>\u25cf\u00a0\u00a0 \u00a0Kvs (stated in m3\/h, calculated based on system power and \u0394T).<\/p>\n<p>Also note that certain water-glycol mixtures used in floor heating circuits may affect pump efficiency.<\/p>\n<p>Example of an installation with circulation units equipped with actuators, from ESBE<\/p>\n<h3><strong>2. Quick installation<\/strong><\/h3>\n<p>Installing a circulation unit takes much less time than having all individual components installed. Installation should be done as instructed, which can be summarised as follows:<\/p>\n<p>1.\u00a0\u00a0 \u00a0Prepare and clean the surface where the circulation unit is to be placed.<br \/>2.\u00a0\u00a0 \u00a0Remove the insulation shell from the circulation unit in order to access the connections.<br \/>3.\u00a0\u00a0 \u00a0Attach and seal the screws. Apply gaskets. Tighten all pipes.<br \/>4.\u00a0\u00a0 \u00a0Assemble the insulation shell and connect power.<br \/>5.\u00a0\u00a0 \u00a0Turn on the pump. Make sure it is working correctly, and that there are no leaks in the system.<\/p>\n<p>\u00a0<\/p>\n<div><iframe src=\"https:\/\/www.youtube.com\/embed\/bIJvjeye4so\" width=\"560\" height=\"315\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\" data-mce-fragment=\"1\"><\/iframe><\/div>\n<p>\u00a0<\/p>\n<h3><strong>3. Easy disassembly and expansion<\/strong><\/h3>\n<p>In case the valve, the actuator, or the pump fails, it takes only a few seconds for the installer to remove the circulation unit\u2019s insulation shell and replace the faulty part. The actuator can be removed from the rotary valve without tools (thanks to the QuickFit connection).<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f2fdeeb at-image-animation at-animation-image-none elementor-widget elementor-widget-image\" data-id=\"f2fdeeb\" data-element_type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"480\" height=\"474\" src=\"https:\/\/thermovent.th.staging.generation-y.net\/wp-content\/uploads\/2023\/06\/Quickfit_EN2.jpg\" class=\"attachment-large size-large wp-image-15541\" alt=\"\" srcset=\"https:\/\/thermovent.th.staging.generation-y.net\/wp-content\/uploads\/2023\/06\/Quickfit_EN2.jpg 480w, https:\/\/thermovent.th.staging.generation-y.net\/wp-content\/uploads\/2023\/06\/Quickfit_EN2-300x296.jpg 300w\" sizes=\"(max-width: 480px) 100vw, 480px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ceb26c9 elementor-widget elementor-widget-text-editor\" data-id=\"ceb26c9\" data-element_type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><small>\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0The QuickFit connection \u2014 just one click, and it\u2019s ready<\/small>\u00a0<\/p>\n<p>\u00a0<\/p>\n<p>Circulation units are suitable for manifolds dedicated to a number of different devices. When expanding the heating system, more than one circulation unit\u00a0can be installed on larger manifolds. Then, one circulation unit\u00a0with an actuator may operate the heater circuit, with another one operating the floor heating circuit. The assortment also includes manifolds with a hydraulic clutch.<\/p>\n<p>\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fce8f03 at-image-animation at-animation-image-none elementor-widget elementor-widget-image\" data-id=\"fce8f03\" data-element_type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"623\" height=\"378\" src=\"https:\/\/thermovent.th.staging.generation-y.net\/wp-content\/uploads\/2023\/06\/GMA4x1_image_650x650px2.jpg\" class=\"attachment-large size-large wp-image-15542\" alt=\"\" srcset=\"https:\/\/thermovent.th.staging.generation-y.net\/wp-content\/uploads\/2023\/06\/GMA4x1_image_650x650px2.jpg 623w, https:\/\/thermovent.th.staging.generation-y.net\/wp-content\/uploads\/2023\/06\/GMA4x1_image_650x650px2-300x182.jpg 300w\" sizes=\"(max-width: 623px) 100vw, 623px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-57a38ba elementor-widget elementor-widget-text-editor\" data-id=\"57a38ba\" data-element_type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><small>\u00a0<\/small><small>Examples of\u00a0<a href=\"https:\/\/www.thermovent.gr\/el\/products\/esbe-gma400?option_variant_id=0\" target=\"_blank\" rel=\"noopener\">GMA400<\/a>\u00a0manifolds:<br \/>for a single circulation unit, for two circulation units<\/small><\/p>\n<p>\u00a0<\/p>\n<h3><strong>4. Excellent insulation<\/strong><\/h3>\n<p>The circulation units\u2019s insulation shell is made from EPP\u2014a material much more resistant to physical factors than the popular styrofoam. Additionally, EPP conforms to stringent EU standards. Individual components of the entire circulation unit\u00a0are appropriately insulated. This dedicated insulation reliably protects the installation from heat losses, and can be removed easily when required.<\/p>\n<p>The circulation units is a proven solution, with many years\u2019 history\u2014and in ESBE they keep developing it to meet the ever-changing market expectations and installation parameters.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9e5c922 at-image-animation at-animation-image-none elementor-widget elementor-widget-image\" data-id=\"9e5c922\" data-element_type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"650\" height=\"650\" src=\"https:\/\/thermovent.th.staging.generation-y.net\/wp-content\/uploads\/2023\/06\/EW116b_PL_circ.unit_technical_news_May_2023_insulation_1080x1080.jpg\" class=\"attachment-large size-large wp-image-15543\" alt=\"\" srcset=\"https:\/\/thermovent.th.staging.generation-y.net\/wp-content\/uploads\/2023\/06\/EW116b_PL_circ.unit_technical_news_May_2023_insulation_1080x1080.jpg 650w, https:\/\/thermovent.th.staging.generation-y.net\/wp-content\/uploads\/2023\/06\/EW116b_PL_circ.unit_technical_news_May_2023_insulation_1080x1080-300x300.jpg 300w, https:\/\/thermovent.th.staging.generation-y.net\/wp-content\/uploads\/2023\/06\/EW116b_PL_circ.unit_technical_news_May_2023_insulation_1080x1080-150x150.jpg 150w\" sizes=\"(max-width: 650px) 100vw, 650px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Circulation unit is a compact set of devices, consisting on various, carefully [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":15525,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[26,29],"tags":[],"class_list":["post-15521","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","category-tips-solutions"],"_links":{"self":[{"href":"https:\/\/thermovent.th.staging.generation-y.net\/en\/wp-json\/wp\/v2\/posts\/15521","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/thermovent.th.staging.generation-y.net\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/thermovent.th.staging.generation-y.net\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/thermovent.th.staging.generation-y.net\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/thermovent.th.staging.generation-y.net\/en\/wp-json\/wp\/v2\/comments?post=15521"}],"version-history":[{"count":7,"href":"https:\/\/thermovent.th.staging.generation-y.net\/en\/wp-json\/wp\/v2\/posts\/15521\/revisions"}],"predecessor-version":[{"id":15556,"href":"https:\/\/thermovent.th.staging.generation-y.net\/en\/wp-json\/wp\/v2\/posts\/15521\/revisions\/15556"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/thermovent.th.staging.generation-y.net\/en\/wp-json\/wp\/v2\/media\/15525"}],"wp:attachment":[{"href":"https:\/\/thermovent.th.staging.generation-y.net\/en\/wp-json\/wp\/v2\/media?parent=15521"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/thermovent.th.staging.generation-y.net\/en\/wp-json\/wp\/v2\/categories?post=15521"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/thermovent.th.staging.generation-y.net\/en\/wp-json\/wp\/v2\/tags?post=15521"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}